Znanstveni radovi objavljeni u časopisima s međunarodnom recenzijom koji su indeksirani u Current Contentsu

(Razdoblje: 1976 - 2006)

 

 

1.      Nj. Radić, Determination of Nanomole Amounts of Aluminium by Use of a Fluoride Ion-selecive Electrode, Analyst, 101 (1976) 657.

2.      Nj. Radić, Metal (Fe3+ , Cu2+) - EDTA Complex Formation Studies in Ethanol-Aqueous Mixtures with Cupric Ion-selective Electrode, Anal. Lett., 12 (A2) (1979) 115.

3.      Nj. Radić and M. Milišić, Sulfide Ion-selective Electrode as Potentiometric Sensor for Lead(II) Ion in Aqueous and Nonaqueous Medium, Anal. Lett.,  13 (A12) (1980) 1013.

4.      Nj. Radić, The Potential Response of Copper(II) Sulfide Ion Selective Electrode to Hg(II) Ions in Aqueous Solution, Anal. Lett., 14 (A14) (1981) 125.

5.      S. P. Brimer, T. H. Ridgway, Nj. Radić and H. B. Mark, Jr., A Simple  Inexpensive 4 1/2 Digit Microvolt Meter for Potentiometric Titrations, Chem., Biomed. and Environ. Inst., 12 (3) (1982) 171.

6.      Nj. Radić and H. B. Mark, Jr.,  A Polymeric Sulfur Nitride, (SN)x, Electrode Responsive to pH and Its Application to The Aqueous Potentiometric Titration of Weak Acids, Anal. Chim. Acta, 144 (1982) 253.

7.      Nj. Radić, K. J. Mulligen and H. B. Mark, Jr., Chemical Pretreatment of Silver Wire Containing Copper for Preparation of Silver/Silver Sulfide Ion Selective Electrode, Anal. Chem., 56 (1984) 297.

8.      Nj. Radić, K. J. Mulligan and H. B. Mark, Jr., The Ion-selective Behaviour of The Polymeric Sulfur Nitride Electrode for The Measurements of Silver(I), Analyst 109 (1984) 963.

9.      Nj. Radić and M. Vudrag, Kinetic Determination of Fe(III) with a Copper(II) Selective Electrode Based on a Metal Displacement Reaction, J. Electroanal. Chem., 178 (1984) 321.

10.  Nj. Radić and H. B. Mark, Jr., A Silver/Silver Sulfide Selective Micro-Electrode Preparated by Chemical Treatment of Silver Wire, Croat. Chem. Acta, 58 (1985) 179.

11.  Nj. Radić, Potentiometric Response of a Commercial (Ag2S + PbS)-Membrane Selective Electrode to Hg(II) in Aqueous Solution, Mikrochim. Acta, I (1985) 209.

12.  J. Komljenović and Nj. Radić, Use of a Multi-purpose Solid-state Ion-selective Electrode Body and AgI-based Membrane  Hydrophobised by PTFE for Determination of  I- and Hg2+, Analyst,111 (1986) 887.

13.  J. Komljenović, S. Krka and Nj. Radić, All-Solid-State Fluoride Electrode, Anal. Chem., 58 (1986) 887.

14.  Nj. Radić, D. Prugo and M. Bralić, Potentiometric Titration of Aluminium with Fluoride in Organic Solvent + Water Mixtures by Use of a Fluoride-selective Electrode, J. Electroanal. Chem., 248 (1988) 87.

15.  Nj. Radić, Solid-State Electrodes Sensitive to Mercury Ions, Selective Electrode Rev., 11 (1989) 87.

16.  Nj. Radić and M. Bralić, Kinetic-Potentiometric Determination of Aluminium in Acid Solution Using Fluoride Ion-selective Electrode, Analyst, 115 (1990) 737.

17.  J. Komljenović, V. Martinac and Nj. Radić, Ion-sensitive Behaviour of The Silver Sulphide-Based Solid-State Copper(II) and Iodide Electrodes in Partially Aqueous Systems, Anal. Chim. Acta, 231 (1990) 137.

18.  J. Komljenović and Nj. Radić, Potentiometric Determination of Thiourea by Using Ion-selective Electrode with AgI-based Membrane Hydrophobised with PTFE, Acta Pharm. Jugosl., 41 (1991) 41.

19.  Nj. Radić and J. Komljenović, Potentiometric Determination of Mercury(II) and Thiourea in Strong Acid Solution Using an Ion-selective Electrode with AgI-based Membrane Hydrophobised by PTFE,  Fresenius J. Anal. Chem., 341 (1991) 592.

20.  Nj. Radić and J. Komljenović, Kinetic-Potentiometric Determination of Fe(III) Using Fluoride Ion-selective Electrode, Croat. Chem. Acta, 64 (1991) 679.

21.  Nj. Radić and J. Komljenović, Potentiometric Determination of an Overall Formation Constant Using an Ion-Selective Membrane Electrode, J. of Chem. Ed., 70 (1993) 509.

22.  Nj. Radić and M. Bralić, Design of Fluoride-selective Electrode with Internal Contact Based on an Cu(II) Ion-selective Electrode, Microchem. J., 48 (1993) 377.

23.  J. Komljenović and Nj. Radić, Potentiometric determination of N-acetylcysteine based on its reduction action on Fe(III), Acta Pharm., 43 (1993) 99.

24.  M. Bralić and Nj. Radić, Direct Potentiometric Measurements of Cysteine by Using Iodide-Selective Electrode, Croat. Chem. Acta, 67 (1994) 543.

25.  Nj. Radić and M. Papa, Solid-state electrode with a Cu(I)-based membrane hydrophobised by PTFE for the measurement of Cu2+ and I-, Fresenius J. Anal. Chem., 351 (1995) 599.

26.  J. Komljenović and Nj. Radić, Design and properties of flow-through electrode with AgI-based membrane hydrophobized by PTFE; application to flow-injection determination of thiourea, Sensors and Actuators: B. Chemical, 24 (1995) 312.

27.  N. Akmal, S. K. Lunsford, A. Galal, A. E. Karagozler, H. B. Mark, Jr. and Nj. Radić, "Programmable" Selective Inexpensive Potentiometric Detector for Flow Injection Analysis. Potassium Determination with a Nafion Membrane Modified Electrode, Croat. Chem. Acta, 68 (1995) 403.

28.  Nj. Radić and M. Papa, Electroanalytical Study of Aluminium Fluoride Complexation in 2-Propanol-Water Mixtures, Analytical Sciences, 11 (1995) 425.

29.  Nj. Radić and M. Bralić, Fluoride-selective Electrode with Internal Redox Reference Electrode, Mikrochim. Acta, 118 (1995) 221.

30.  Nj. Radić and M. Bralić, Aluminium fluoride complexation and its ecological importance in the aquatic environment, Sci Total Environ., 172 (1995) 237.

31.  J. Komljenović and Nj. Radić, Potentiometric flow-injection determination of cysteine in the presence of cystine using an tubular electrode with AgI-based membrane as detector, Analusis, 24 (1996) 63.

32.  Nj. Radić and J. Komljenović, Determination of N-acetyl-L-cysteine by flow-injection potentiometry, Fresenius J. Anal. Chem., 360 (1998) 675.

33.  Nj. Radić and J. Komljenović, Flow-injection determination of compounds containing sulphur by using potentiometric tubular sensor, Laboratory Robotics and Automation, 10 (1998) 143.

34.  M. Bralić and Nj. Radić, Flow injection potentiometric determination of Fe(III) using a fluoride selective electrode as detector, Analusis, 27 (1999) 57.

35.  D. Dobčnik, M. Kolar, J. Komljenović and Nj. Radić, Preparation of an ion-selective electrode by chemical treatment of copper wire for the measurement of copper(II) and iodide by batch and flow-injection potentiometry, Fresenius J.Anal. Chem.,365 (1999) 314.

36.  Nj. Radić, J. Komljenović and D. Dobčnik, Determination of Penicillamine by Batch and Flow-injection Potentiometry with AgI-based sensor, Croat. Chem. Acta, 73 (2000) 263.

37.  M.Kolar, D. Dobčnik and Nj. Radić, Potentiometric Flow-injection Determination of Vitamin C and Glutathione with a Chemical Prepared Tubular Silver Electrode, Pharmazie, 55 (2000) 913.

38.  Nj. Radić and D. Dobčnik, Surface Compounds and Reactions in Relation to the Response of Solid-state Potentiometric Chemical Sensors, Surf. Rev. Letters, 8 (2001) 361.

39.  M. Bralić, Nj. Radić, S. Brinić and E. Generalić, Fluoride Electrode with LaF3-Membrane and Simple Disjoining Solid-State Internal Contact, Talanta, 55 (2001) 581.

40.  M. Kolar, D. Dobčnik and Nj. Radić, Chemically Treated Silver Electrodes for the Determination of Cysteine, Mikrochimica Acta, 138 (2002) 23.

41.  Nj. Radić and J. Komljenović, Potential Response of Solid State Potentiometric Chemical Sensors, Theoretical Approach and Teaching Experiment, Acta Chim. Slov. 52 (2005)  450.

42.  L. Kukoč-Modun and Nj. Radić, Potentiometric Determination of N-(2–Mercaptopropionyl)-glycine Using Electrode with AgI-based Membrane, Croat. Chem. Acta, 79 (2006) xx.